Approved treatment devices and systems
Approved private well components
Approved components for Alternative Discharging (stream discharging) Systems (under construction)
Conveyance Line / Distribution Boxes / Filter Fabric / Filters / Flow Dividers / Header Line / Inlet and Outlet Structures / Perforated Pipe / Pipe Connectors / Pipe Seals / Pipe Primer / Privy / Pump Chambers / Septic Tank / Sewer Line
Component Type |
Manufacturer |
Product |
Approval |
Additional Information |
Conveyance Line |
||||
---|---|---|---|---|
TBA, Inc. | 3″, 4″, and 6″ solid pipe | GMP 13 | ||
Distribution Boxes |
||||
Bethlehem Manufacturing Company, Inc. | VA-001-D, and VA-002-D | GMP 3 | Drawings | |
FRALO | Monster D-box | Vehicular traffic loading situations | ||
Tuf-Tite | Distribution Box | GMP 73 | Prior Approvals | |
Winchester Building Supply | Distribution Box | GMP 120 | Distribution Box Form Approvals | |
Zoeller | Model 173-0001 | GMP 110 | ||
Polylok | Rhino Box (8 and 10 hole) | Approval MEMO Polylok Rhino D Box 04 24 2020 | Rhino_Dbx_listingdocs_042120 | |
Filter Fabric |
||||
Avgol | Polypropylene nonwoven filter fabric | GMP 63 | ||
Mirafi | 140N Drainage Fabric | GMP 45 | Product literature | |
Filters |
||||
SIM/TECH Filters | GAG | GMP 94 | ||
Flow Dividers |
||||
Flow Divider Company | Flow Divider Tee | GMP 7 | ||
Header Line |
||||
Advanced Drainage Systems Inc. | ADS-3000 pipe | GMP 89 | ||
TBA, Inc. | 4″ solid pipe | GMP 13 | ||
Inlet and Outlet Structures |
||||
United Concrete Products, Inc. | United Baffle | GMP 38 | Product literature | |
Perforated Pipe |
||||
Advanced Drainage Systems Inc. | ADS-3000 pipe | GMP 89 | ||
TBA, Inc. | 4″ perforated pipe | GMP 13 | ||
Pipe Connectors |
||||
Tuf-Tite | Pipe Connectors | GMP 11 | ||
Pipe Seals |
||||
United Concrete Products | Pipe Seals | GMP 34 | Product literature | |
Pipe Primer |
||||
Charlotte Pipe and Foundry Company | Primer on PVC-DWV Foam Core Pipe | GMP 8 | Letter from Charlotte Pipe and Foundry | |
Privy |
||||
Enviro Loo | Eloo Privy – Model 2040 | GMP 134 | PE plans – top view , PE plans – side view, PE plans – bottom view. | |
Incinolet | Electric Toilet | GMP 42 | Product literature | |
Pump Chambers |
||||
Design Pro of Duluth, Inc. | 500 gallon top seam tank | GMP 108 | ||
Infiltrator Water Technologies | IM-540 | Approval Letter | ||
Infiltrator Water Technologies | TW-300, TW-375, TW-500, TW-900, TW-1050, IM-1060, TW-1250, TW-1500 | Approval Letter | ||
Infiltrator Water Technologies | HDPE tanks, TW-300, TW-375, TW-500, TW-900, TW-1050, TW-1250, TW-1500 | Approval Letter | TW-300 drawing , TW-500 drawing , approval request | |
Martinsburg Concrete Products | 500 gallon pump tanks, standard and top seam | GMP 108 | ||
Norwesco | Model numbers 41734, 41752, 41771, 41735, 41753, 41772 | Approval Letter | ||
Septic Tank |
||||
AK Industries | 1000 gallon polyethylene septic tank | GMP 77 | Tank specifications(please not 500 and 750 gallon tanks not approved) | |
Allied Signal Inc. | Caprolan – RC Fibers | GMP 16 | Product literature | |
Bethlehem Manufacturing Company, Inc. | VA006, and VA007 | GMP 6 | Plans and specifications | |
Bethlehem Manufacturing Company, Inc. | VA008, VA009, and VA010 | GMP 10 | Product specifications | |
Bethlehem Manufacturing Company, Inc. | VA011 | GMP 26 | Plans and Specifications | |
Bethlehem Manufacturing Company, Inc. | VA012, VA013 | GMP 65 | Plans and specifications | |
Bethlehem Manufacturing Company, Inc. | VA014, VA015 | GMP 83 | ||
Coon Manufacturing | 1000 and 1500 gallon septic tanks | GMP 131 | Approval letter , Tank Drawings | |
Design Pro of Duluth, Inc. | 1000 and 1500 gallon top seam tank, 1500 gallon two compartment tank | GMP 108 | ||
FORTA Corporation | FORTA Nylon and FORTA CFP reinforcement fiber in septic tanks | GMP 82 | ||
Infiltrator Water Technologies | IM-1530 Low Profile Septic Tank;
TW-900; TW-1050; IM-300; IM-1250; IM-1060; CM-1060; TW-1250; TW-1500 |
Approval Letter
VA_TW-and-IM-1060_approval-letter_032211-1 (1) Infiltrator CM 1060 updated approval memo |
Specifications , Approval Request | |
Jolin Concrete Industries | CP001076, CP001077, CP001079 | GMP 104 | ||
Martinsburg Concrete Products | 1000, 1250, and 1500 gallon septic tanks with fiber mesh | GMP 84 | ||
Martinsburg Concrete Products | Standard tanks and top seam tank with 1000 and 1500 gallon capacities | GMP 108 | ||
ME Concrete Products | 1500 and 2000 g single and two compartment tanks | Approval MEMORANDUM – ME Concrete ProductsST_062518 | Combined MEC docs | |
Norwesco | Low profile polyethylene single and dual compartment septic tanks: 1000; 1250; and 1500 gallon. | GMP 139 | Approval letter ,Schematic Tank Drawings | |
Norwesco, Inc. | Product item numbers 40018, 40006, 40187, 40325, 40276 | GMP 40 | Product literature (please note 300 and 500 gallon tanks not approved) | |
Norwesco | Model numbers 41712, 41718, 41741, and 41758 | Approval Letter | ||
Norwesco | 750, 1000, 1250, and 1500 gallon low profile septic tanks | Approval Letter | 750 specs , 750 capacity table , 1000 specs , 1000 capacity table, 1250 specs , 1250 capacity table , 1500 specs , 1500 capacity table | |
Roth Global Plastics | RMT Septic Tanks | GMP 133.A | Prior approval under different name. | |
Roth Global Plastics | RMT 500 | Approval Letter | Request for Approval,Installation Manual,Brochure | |
Rotoplas USA | HDPE 750, 1000, 1500 two compartment septic tanks | Approval MEMORANDUM – Rotoplas_081518 | RotoplasST_Supporting Docs_082118 | |
SEPTECH | Septic Tank Models ST-750, ST-1060, ST-1250, and ST-1500 | GMP 129 | ST 750 drawing , ST 1060 drawing,ST 1250 drawing,ST 1500 drawing, Typical Cross Section | |
Snyder Industries, Inc. | Dominator | GMP 151 | ||
T&N Fiberglass Manufacturing Company, Inc. | 1000 gallon septic tank | GMP 55 | Specifications | |
Winchester Building Supply | Septic Tank | GMP 120 | Septic Tank Form Approval | |
Xactics | Model numbers 142800, 143400, 143600, 143605, 145500 | GMP 76 | Xactics product literature | |
Sewer Line |
||||
Plastic Tubing Incorporated | CORR-A-FLOW | GMP 31 | Product Literature | |
SDR 35 Pipe | SDR 35 Pipe | GMP 5 |
Note: The omission of a particular product or products from the listing is not a statement of unsuitability because products that comply with application health department regulations are not subject to review. Therefore, many suitable products are not specifically listed on these pages as “approved.” VDH does not endorse or recommend any particular product or manufacturer and an approval does not denote or imply any warranty or guarantee as to the fitness of the product for a particular use, nor should one be inferred.